Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Vasc Surg Cases Innov Tech ; 6(2): 292-306, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32566808

RESUMO

Stenosis due to neointimal hyperplasia (NIH) is among the major causes of peripheral graft failure. Its link to abnormal hemodynamics in the graft is complex, and isolated use of hemodynamic markers is insufficient to fully capture its progression. Here, a computational model of NIH growth is presented, establishing a link between computational fluid dynamics simulations of flow in the lumen and a biochemical model representing NIH growth mechanisms inside the vessel wall. For all three patients analyzed, NIH at proximal and distal anastomoses was simulated by the model, with values of stenosis comparable to the computed tomography scans.

2.
Med Eng Phys ; 74: 137-145, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31540730

RESUMO

Neointimal hyperplasia (NIH) is a major obstacle to graft patency in the peripheral arteries. A complex interaction of biomechanical factors contribute to NIH development and progression, and although haemodynamic markers such as wall shear stress have been linked to the disease, these have so far been insufficient to fully capture its behaviour. Using a computational model linking computational fluid dynamics (CFD) simulations of blood flow with a biochemical model representing NIH growth mechanisms, we analyse the effect of compliance mismatch, due to the presence of surgical stitches and/or to the change in distensibility between artery and vein graft, on the haemodynamics in the lumen and, subsequently, on NIH progression. The model enabled to simulate NIH at proximal and distal anastomoses of three patient-specific end-to-side saphenous vein grafts under two compliance-mismatch configurations, and a rigid wall case for comparison, obtaining values of stenosis similar to those observed in the computed tomography (CT) scans. The maximum difference in time-averaged wall shear stress between the rigid and compliant models was 3.4 Pa, and differences in estimation of NIH progression were only observed in one patient. The impact of compliance on the haemodynamic-driven development of NIH was small in the patient-specific cases considered.


Assuntos
Prótese Vascular/efeitos adversos , Simulação por Computador , Neointima/etiologia , Neointima/patologia , Artérias/diagnóstico por imagem , Artérias/patologia , Artérias/fisiopatologia , Artérias/cirurgia , Progressão da Doença , Hemodinâmica , Humanos , Hidrodinâmica , Hiperplasia/patologia , Neointima/diagnóstico por imagem , Neointima/fisiopatologia , Modelagem Computacional Específica para o Paciente , Tomografia Computadorizada por Raios X
3.
Front Physiol ; 8: 226, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28458640

RESUMO

Neointimal hyperplasia is amongst the major causes of failure of bypass grafts. The disease progression varies from patient to patient due to a range of different factors. In this paper, a mathematical model will be used to understand neointimal hyperplasia in individual patients, combining information from biological experiments and patient-specific data to analyze some aspects of the disease, particularly with regard to mechanical stimuli due to shear stresses on the vessel wall. By combining a biochemical model of cell growth and a patient-specific computational fluid dynamics analysis of blood flow in the lumen, remodeling of the blood vessel is studied by means of a novel computational framework. The framework was used to analyze two vein graft bypasses from one patient: a femoro-popliteal and a femoro-distal bypass. The remodeling of the vessel wall and analysis of the flow for each case was then compared to clinical data and discussed as a potential tool for a better understanding of the disease. Simulation results from this first computational approach showed an overall agreement on the locations of hyperplasia in these patients and demonstrated the potential of using new integrative modeling tools to understand disease progression.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...